Products Description
Our ngr system combines the grounding transformer, resistor, current transformer, isolating switch, intelligent monitor, and cabinet. The transformer may use dry or oil-immersed insulation according to the selected configuration.
Technical Principle
The transformer creates an artificial neutral point for a system that otherwise has no accessible neutral. During a ground fault, zero-sequence current flows through the grounding path so the connected resistor or arc-suppression coil can limit or compensate fault current.

Product Features
The ngr system places the main grounding and monitoring functions in one coordinated package. Multiple connection groups and insulation forms support different neutral-point designs. The integrated current transformer and monitor provide operating information for protection coordination. A cabinet-based arrangement simplifies site wiring and equipment organization.
Operating Conditions
The product shall be installed and operated within the ratings stated in the technical parameters. Key site requirements include: altitude, and seismic conditions.; frequency. Keep the installation area clean, adequately ventilated, free from corrosive gas and severe vibration, and provide the specified grounding, clearance, and power quality.

Product Parameters
|
Parameter |
Details |
|
Grounding-transformer capacity |
≤5000 kVA |
|
Voltage range |
66 kV, 35 kV, and below |
|
Tap range |
±2×2.5% or ±5% |
|
Phase / frequency |
Three phase / 50 Hz or 60 Hz |
|
Connection options |
Zn,yn11; Zn,yn1; or Zn |
|
Insulation options |
F-class dry type; A- or B-class oil immersed |
|
Long-term temperature rise |
100 K |
|
Maximum applied voltage |
Generally ≤105% of rated tap voltage |
|
Installation altitude |
≤3000 m |
|
Seismic requirement |
Seismic intensity ≤8 |
Product Advantages
- The ngr system places the main grounding and monitoring functions in one coordinated package.
- Multiple connection groups and insulation forms support different neutral-point designs.
- The integrated current transformer and monitor provide operating information for protection coordination.
- A cabinet-based arrangement simplifies site wiring and equipment organization.
Main Applications
The ngr system is used for medium- and high-voltage networks that require a grounding transformer with low-resistance fault-current limitation.
It suits substations, industrial distribution systems, power plants, and renewable-energy collection networks.
The package is selected when the system has no accessible neutral point.
Components
|
Part |
Function |
|
Grounding transformer |
Creates the neutral point for the grounding branch. |
|
Neutral grounding resistor |
Limits the ground-fault current to the design value. |
|
CT and isolating switch |
Provide measurement and safe circuit isolation. |
|
Monitor and cabinet |
Handle status supervision, protection interfaces, and enclosure. |
FAQ
Q: What information is needed for model selection?
A: Confirm voltage, transformer capacity, grounding current, resistor duty time, connection group, and secondary load.
Q: What should be checked before installation?
A: Verify cabinet location, cable routes, grounding conductor size, ventilation, altitude, and seismic conditions.
Q: How can the device or system be integrated?
A: Current-transformer and intelligent-monitor signals can be wired to the station protection or supervisory platform.
Q: Which options should be confirmed before production?
A: Confirm dry or oil insulation, switch arrangement, fiber-temperature option, cabinet protection, and entry direction.