Products Description
Our 3 phase dry type transformer combines three dry-insulated phase windings with temperature supervision and optional forced ventilation. The arrangement is intended for clean operation without an oil tank. The three-phase unit is configured as an integrated distribution transformer rather than a grounding-only device. Its primary design task is continuous transfer of three-phase load power. Cast coils provide mechanical restraint and moisture resistance, while axial and radial air passages support natural-air or forced-air cooling. Temperature sensors may be embedded in the low-voltage winding to supervise hot-spot rise and operate fans or alarms. Typical project checks include phase sequence, vector group, neutral accessibility, tap position, enclosure ingress protection, ventilation opening area, cable termination space, and fire-clearance requirements. Before energization, insulation resistance, winding resistance, ratio, connection group, core grounding, fan direction, temperature-controller wiring, and protective-earth continuity should be verified. During service, air passages should remain unobstructed and dust accumulation should be controlled so the designed cooling path is maintained.
Technical Principle
This three-phase dry-type design uses cast-resin insulated windings and a laminated magnetic core to transform station-service voltage without liquid insulation. Phase geometry, winding connections, insulation class, cooling ducts, and enclosure ventilation are coordinated to control short-circuit stress, partial discharge, noise, and temperature rise. The product is intended for indoor distribution locations where fire safety, low maintenance, and clean operation are important.

Product Features
The 3 phase dry type transformer provides a three-phase station supply in a compact dry construction. Temperature supervision supports alarm and cooling control for the winding set. No oil tank is required, which simplifies indoor fire and containment planning. Selectable enclosure grades help protect the active part from the installation environment.
Operating Conditions
The product shall be installed and operated within the ratings stated in the technical parameters. Key site requirements include: altitude.. Keep the installation area clean, adequately ventilated, free from corrosive gas and severe vibration, and provide the specified grounding, clearance, and power quality.

Product Parameters
|
Parameter |
Details |
|
Phase arrangement |
Three phase |
|
Model example |
SCB18-2500/33/0.4 |
|
Energy-performance levels |
18: Level 1; 14: Level 2; 12: Level 3 |
|
Cooling modes |
Natural air (AN) or forced air (AF) |
|
Enclosure options |
IP3X, IP5X, or IP6X |
|
Ambient-temperature limit |
≤40°C |
|
Installation altitude |
≤1000 m without stated derating |
|
Required ventilation |
4 m³/min per 1 kW of total loss |
Product Advantages
- The 3 phase dry type transformer provides a three-phase station supply in a compact dry construction.
- Temperature supervision supports alarm and cooling control for the winding set.
- No oil tank is required, which simplifies indoor fire and containment planning.
- Selectable enclosure grades help protect the active part from the installation environment.
Main Applications
The 3 phase dry type transformer is used for three-phase auxiliary distribution in substations, power plants, factories, and renewable-energy stations.
It is appropriate for indoor locations with controlled ventilation.
The unit supplies station equipment that requires a dedicated low-voltage source.
Components
|
Part |
Function |
|
Three-phase core |
Carries the alternating magnetic flux. |
|
Dry winding assembly |
Provides the specified primary and secondary voltage transformation. |
|
Temperature sensors |
Send winding-temperature information to the controller. |
|
Enclosure and fan set |
Provide mechanical protection and optional forced cooling. |
FAQ
Q: What information is needed for model selection?
A: Provide the three-phase voltage ratio, capacity, connection group, impedance, and auxiliary-load schedule.
Q: What should be checked before installation?
A: Confirm floor loading, air inlet and outlet area, electrical clearance, and installation altitude.
Q: How can the device or system be integrated?
A: The temperature controller can provide fan, alarm, and trip contacts for station wiring.
Q: Which options should be confirmed before production?
A: Select the efficiency code, enclosure, cooling mode, tapping, terminals, and monitoring accessories.