Products Description
Our dry type power transformer uses a dry insulation structure designed for low loss, low partial discharge, flame resistance, and short-circuit strength. The enclosure grade can be selected for the station environment. This SW-SCB station-service transformer emphasizes compact indoor installation and low routine maintenance. The high-voltage and low-voltage windings are insulated with dry solid materials, so no oil collection pit or liquid-leak management is required. The core is assembled from low-loss electrical steel and clamped to limit vibration. Depending on capacity and thermal design, cooling is by natural air or fan-assisted air. The product can be supplied with an enclosure, temperature monitor, fan controller, alarm contacts, and communication interface. Selection should consider continuous load, short-time overload, harmonic content, ambient ventilation, altitude correction, insulation class, permissible temperature rise, short-circuit impedance, and coordination with upstream protection. Installation requires dry foundations, unobstructed air passages, correct phase spacing, secure cable support, and reliable grounding of the frame and enclosure. Dust and conductive contamination should be removed periodically because blocked ducts reduce cooling performance.
Technical Principle
Electromagnetic induction transfers energy between isolated windings at the specified voltage ratio. The magnetic core guides flux, while the insulation and cooling structure maintain dielectric strength and temperature rise within design limits.

Product Features
The dry type power transformer avoids insulating oil in the station-service transformer area. The dry construction provides flame-retardant and pollution-free service characteristics. AN and AF choices allow the cooling arrangement to follow load and ventilation conditions. Several enclosure grades support indoor spaces with different protection requirements.
Operating Conditions
The product shall be installed and operated within the ratings stated in the technical parameters. Key site requirements include: ambient temperature, and installation altitude.; altitude.. Keep the installation area clean, adequately ventilated, free from corrosive gas and severe vibration, and provide the specified grounding, clearance, and power quality.

Product Parameters
|
Parameter |
Details |
|
Series |
SW-SCB |
|
Model example |
SCB18-2500/33/0.4 |
|
Energy-performance codes |
SCB18: Level 1; SCB14: Level 2; SCB12: Level 3 |
|
Cooling method |
AN or AF |
|
Enclosure protection |
IP3X, IP5X, or IP6X |
|
Maximum ambient temperature |
40°C |
|
Standard altitude |
≤1000 m |
|
Ventilation requirement |
4 m³/min of air per 1 kW of transformer loss |
|
Altitude correction |
Derating according to IEC 60076 or IEEE C57 above 1000 m |
Product Advantages
- The dry type power transformer avoids insulating oil in the station-service transformer area.
- The dry construction provides flame-retardant and pollution-free service characteristics.
- AN and AF choices allow the cooling arrangement to follow load and ventilation conditions.
- Several enclosure grades support indoor spaces with different protection requirements.
Main Applications
The dry type power transformer is used for station auxiliary power, control buildings, industrial substations, and indoor distribution rooms.
It is suitable where oil containment or fire-load reduction is important.
The transformer can supply lighting, control, heating, ventilation, and other station loads.
Components
|
Part |
Function |
|
Core and coils |
Perform voltage transformation with a dry insulation structure. |
|
Temperature-control unit |
Supervises winding temperature and fan operation. |
|
Cooling fans |
Provide forced-air cooling when the AF mode is selected. |
|
Protective enclosure |
Provides the specified IP3X, IP5X, or IP6X protection. |
FAQ
Q: What information is needed for model selection?
A: Confirm primary and secondary voltage, rated capacity, vector group, impedance, and station load profile.
Q: What should be checked before installation?
A: Check room ventilation, fire clearance, cable routing, ambient temperature, and installation altitude.
Q: How can the device or system be integrated?
A: Temperature alarms, trips, and fan-control contacts can be connected to station supervision circuits.
Q: Which options should be confirmed before production?
A: Confirm energy level, enclosure grade, cooling method, taps, temperature controller, and accessory layout.
Hot Tags: dry type power transformer, China dry type power transformer manufacturers, suppliers, factory