Automatic Transformer Cooling Controller

Send Inquiry
Automatic Transformer Cooling Controller
Details
The automatic transformer cooling controller is built around the SW-BFG programmed controller platform for executing temperature- and load-based fan and pump switching logic. The stated program starts auxiliary cooling at 55°C and removes it below 45°C.
Category
Transformer Cooling Control Cabinet
Share to
Description

Products Description

Our automatic transformer cooling controller handles dual-power transfer, automatic cooler rotation, load-start input, manual override, and fault outputs. Working and auxiliary coolers rotate at the stated interval to share operating time.

 

Technical Principle

Temperature, load, oil-flow, fan, and pump feedback are collected by the controller. Programmed logic starts, stops, rotates, and transfers cooling groups according to configured thresholds while issuing fault alarms and recording operating status.

product-800-800

 

Product Features

The automatic transformer cooling controller applies a defined temperature sequence without continuous operator action. Thirty-day rotation shares operating hours between main and auxiliary cooler groups. Dual-power transfer preserves control when the selected source fails. Dedicated fault outputs give the station clear indications for protection and alarm handling.

 

Operating Conditions

Install the product in a clean, ventilated location without corrosive gas, conductive dust, water ingress, severe vibration, or strong impact. Provide reliable protective grounding, maintain the required electrical clearances, and use the rated auxiliary power supply. Confirm ambient temperature, humidity, altitude, enclosure protection, cable routing, and communication conditions before production and installation.

product-800-800

 

Product Parameters

Parameter

Details

Control modes

Manual, automatic, and remote

Auxiliary-cooler start

55°C

Auxiliary-cooler stop

Below 45°C

Cooler rotation interval

30 days

Load-start contact

Normally open; closed starts all coolers, open stops them

Dual-power function

Automatic transfer to the alternate source and return after recovery

Full-stop trip with 75°C signal

20-minute delay

Full-stop trip without 75°C signal

1-hour delay

Fault outputs

Cooler fault, all-coolers stopped, PLC fault, supply fault, and DC control-supply fault

Cabinet environment

-25°C to +70°C; ≤95% RH at 25°C; IP55

 

Product Advantages

  • The automatic transformer cooling controller applies a defined temperature sequence without continuous operator action.
  • Thirty-day rotation shares operating hours between main and auxiliary cooler groups.
  • Dual-power transfer preserves control when the selected source fails.
  • Dedicated fault outputs give the station clear indications for protection and alarm handling.

 

Main Applications

The automatic transformer cooling controller is used for transformer fan and oil-pump groups that need automatic start, rotation, and standby transfer.

It supports new cooling cabinets and project-specific control upgrades based on approved logic.

The controller serves utility substations, generation plants, and industrial transformer systems.

 

Components

Part

Function

Programmable controller

Executes temperature, load, rotation, and fault logic.

Dual-power switching circuit

Transfers control power between two sources.

Motor-control outputs

Start or stop working, auxiliary, and standby coolers.

Alarm and trip outputs

Report cooler, PLC, power, and all-stop conditions.

 

FAQ

Q: What information is needed for model selection?

A: Provide the cooler quantity, main and auxiliary grouping, temperature contacts, load input, and trip philosophy.

Q: What should be checked before installation?

A: Verify dual-power phasing, motor interlocks, contact logic, alarm destinations, manual controls, and emergency operation.

Q: How can the device or system be integrated?

A: Hardwired status, alarm, and control signals connect the controller with the transformer and station circuits.

Q: Which options should be confirmed before production?

A: Confirm thresholds, time delays, rotation interval, cooler grouping, output contacts, and remote-control requirements.

 

Hot Tags: automatic transformer cooling controller, China automatic transformer cooling controller manufacturers, suppliers, factory

Send Inquiry